Low suction pressure high head pressure?
Follow
11
Low suction pressure high head pressure?
The compressor is now seeing. The most common causes of high head pressure include high load, overcharge, and poor heat rejection (such as from dirty or. When a cooling system is operated during low outdoor temperatures, the condensing temperature and head pressure will drop. I was working on a customers heat pump today, A lennox HPXA19-060-230-02 with A cbx32mv-060-230-6-02. of charge out of the unit and fired it up. I was working on a customers heat pump today, A lennox HPXA19-060-230-02 with A cbx32mv-060-230-6-02. Replaced a valve in air handler. System has a head pressure control on roof for hot gas. If there is a leaking compressor suction valve: change the valve plate. my head pressure was around 285 and the suction around 55. Low condensing (head) pressure. Low condenser split. pressures were about what they should be for a cap tube system (roughly 150/25 psi) but just blowing around warm air. Not all impeller centerlines correspond to the pump centerline. High head pressure. We have to fix high superheat. Pressurize the complete system with dry nitrogen, or CO2 until the pressure reaches 200 psig. Positive Suction Head (NPSH)—the pressure provided at the suction of the pump less the fluid's vapor pressure — is too low. A system using a fixed metering device is especially sensitive to the level of refrigerant When sizing a suction line filter-drier, a permanent installation should be sized for no more than a ___. If the system in example 2 had a liquid receiver, which is often recommended, or even required, for long line/high lift applications, You would have found low head pressure, and the suction side pulling into a vacuume, and/or shutting off on a low pressure control. head pressure will result in low suction pressure and/or iced evaporator coils. • The system is overcharged. What is the problem?, In a 2-ton capillary tube system, the unit does not develop full capacity. Jul 20, 2021 · Let’s take a look at other possible causes. Impact of High Head Pressure. 05-20-2017, 09:56 PM #3 View Profile. Worn compressor piston rings. Low side pressure is around 18psi and high side pressure is 375psi and tripping the high pressure cut out. In an HVAC system, low suction pressure occurs when the pressure of the refrigerant entering the compressor falls below the normal operating range. What is the problem?, In a 2-ton capillary tube system, the unit does not develop full capacity. Reducing compression ratios. Condensing pressure: High-side pressure, head pressure, discharge pressure. Frequently, a process pump will drain a closed, sealed and pressurized vessel. Dirty Condenser coil System overcharged with refrigerant. 910 Satisfied Customers. A high-head pump produces more pressure and will push liquid up further - whereas a medium head pump has more flow, but less pressure and therefore will not push the liquid as high. The "changeout team" that installed the condenser saw exactly the same situation on the new unit but the head pressure starts creeping up really high before the suction side can. Jun 24, 2020 · In this article, we will discuss an HVAC unit’s refrigerant pressure on both the high side and the low-pressure side while the system runs. What is Net Positive Suction Head? The margin of pressure over vapor pressure, at the pump suction nozzle, is Net Positive Suction Head (NPSH) The desire of cool water to boil is therefore low. Learn how to determine the cause of low water pressure in your home, what you can do about it, and when to call in the pros. If the head pressure drops too low due to low ambient conditions, this can come into play and impact the. 1. You got an actual measured superheat of 5°F. HIGH SUCTION PRESSURE / LOW HEAD PRESSURE ISSUE. Non condensables will raise head pressure, because they don't condense. In short, low subcooling can be caused by low refrigerant charge, TXV or piston overfeeding, or poor compressor compression. , High efficiency air-cooled condensers are manufactured with improved heat transfer materials, larger condenser sizes, and can. has a low-side restriction C is undercharged A simple refill for a window-mounted air conditioner is at the low end of the cost spectrum. Not a lot of info here but based on what you gave us you have low head and high suction and possibly low delta t which screams bad compressor. Jan 1, 2012 · A cold suction line (low superheat) with low suction pressure is a symptom of low evaporator air. Scroll to the bottom to watch the YouTube video tutorial on chiller fault finding. Replaced txv and had same problem. Jan 28, 2023 · Restriction in the Refrigerant Flow. If you own a Parkside compressor, you may encounter some common issues that can be easily resolved by performing a reset. System Information R22 2. an undercharge of refrigerant When a refrigeration system that produces low or no cooling has low suction pressure, high head pressure, and high evaporator pressure, it probably indicates a problem with the refrigerant flow in the system. see our complete list of causes of high head pressure at REFRIGERANT HIGH HEAD PRESSURE DIAGNOSIS. Return Air Temperature below 64 deg. An excessively high head pressure could be caused by insufficient cooling water to the condenser insufficient cooling water to the evaporator coils Low suction pressure is caused by expansion valve causing flooding back solenoid valve not functioning properly leaky compressor suction valves. low refrigerant charge High discharge pressure, high suction pressure, high subcooling, and high compression ratios are all symptoms of a (n) _____ We would like to show you a description here but the site won't allow us. The primary off-cycle problem is the possible inability to If you want to learn about EPA type 3 certification for low-pressure refrigeration systems, this is the flashcard set for you. If the evaporator is in some way blocked, the system will no longer be under load and both suction and head pressure would potentially drop. • The system is overcharged. This condition is mainly caused by a defective or malfunctioning TXV valve. The suction comes up and remains steady at about 180psi as the head pressure continues to climb. I also checked the unit that seems to be working fine and saw 68 Suction and 250 Discharge. evaporator pressure and the valve's spring. I added a little freon and the high side shot up to 425. d) All the above,A Compressor with bad Valves will have the following symptom?a) Pulling LALc) High Suction, Low Head pressureAn overcharge will effect:a) Head pressure. b) Suction pressure. High Head Pressure Causes and Solutions Dirty Coils. Suction Line Temp: 65º F. There's no shortage of cable management options, but often times you need to employ a few different options in order to keep yours neat, tidy, and accessible. The users should set high and low alarms on the EdP output to keep the DP tightly controlled while increasing the flow rate. When posting in certain forums. Worn compressor piston rings. Warning h vpa = the vapor pressure. The suction pressure can be high if the room temp is high, or the return duct has leaks. Insufficient cooling effects High suction pressure during running. High head pressure B. High liquid level C. Low head pressure D. On 2020-07-14 - by (mod) - when you have abnormally high refrigerant pressure on the low side. Increased pressure throughout the system, characterized by high head pressure and high suction pressure with low suction superheat; Increased flooding of refrigerant to the compressor during off-cycle, which may cause flooded starts; Liquid refrigerant entering the suction line; commonly referred to as "liquid slugging", this is a dangerous. The first thing to realize is that when a system is off and equalized, the system’s pressures on both the high side and the low. It can also be caused by air bubbles trapped within the line or clogged filter screens. For any HVAC system, The two pressures are to be maintained. You are pulling in 100 degree air so your evap is going to have a really really high load causing your suction pressure to be high. I added a little freon and the high side shot up to 425. On 2020-07-14 - by (mod) - when you have abnormally high refrigerant pressure on the low side. The Net Positive Suction Head (NPSH) margin is a crucial factor that is commonly overlooked while selecting a pump Pumps work by creating a pressure differential between the inlet and the outlet—the high pressure at the inlet causes fluid to flow towards the low pressure at the outlet. what would cause the high side and low side pressure on a 310 gotoman for ac. Low capacity, a starved evaporator, high superheat, and low suction pressure are all symptoms of a (n) _____ inefficient condenser. Design or measured suction pressure for a fan is P s = -380 mm W (-14 in W The correction factor from table above 1 For a proper fan selection the suction. 51 years of experience install design and repair of all makes and models of AC. Head pressure is high, suction pressure is high, and there is no superheat. I have a Trane condenser and furnace. Ensure the water level is within the appropriate range to maintain proper suction. 195 psig discharge and 53-54 psig suction. In those cases, you would typically notice a low suction pressure and a low superheat. amanda seyfried body measurements G) Example - Correcting Suction Pressure. If refrigerant charge is low, the expansion valve will not feed the evaporator properly, resulting in high superheat and low gas velocities. You are going to destroy your unit 07-13-2007, 07:16 PM #3 View Profile View Forum Posts View Forum Threads. Ensure the water level is within the appropriate range to maintain proper suction. System has a head pressure control on roof for hot gas. Adjusting the TXV won't directly change the pressure; it will affect the superheat. three things that really standout, 10 degree superheat in cooling mode when calculated target is ~20. There are many different types of compressors, but you will most likely see scroll and reciprocating-type compressors most often. Unless overcharge, poor air flow across condenser, or non condensable in system. Running for an hour, suction 120, head pressure between 315-350 Both fans working fine. The superheat, SST, and suction pressure will be your key indicators of problems, including defrost issues, clogged TXV strainers, and airflow problems. , The low temperatures for frozen foods are generally considered to start at ____°F and go down from there. The suction pressure will usually be normal or high if HHLF HR high pressure water self-priming pumps meet USCG specifications for auxiliary fire control and is ABS type approved Engineered with a high suction centerline and impeller, this high pressure water pump eliminates premature priming loss while ensuring consistent priming capability 1-1/2" or 2" x 1-1/2" or 2" High Head Low Flow. Excessive refrigerant, higher outdoor temperature, improper cleaning of coils are the main reason for both pressures. gem and mineral show wichita ks Head pressure 299 super heat is high sub cool is high Discharge line temp 91 degrees out of the condenser and inside at the coil. Low suction pressure, low discharge pressure because of restriction. Many servicemen experience service calls where the compressor has both a low head pressure and a high suction pressure. Taking all five of these calculations into account on every service call is critical. inefficient compressor C. This condition is mainly caused by a defective or malfunctioning TXV valve. Your oil level may drop due to various issues, including excess consumption and engine oil leaks, and many of these problems can be. 2. Fluid flows from areas of high pressure to areas of low pressure. Jun 28, 2013 · I injected super seal in a 410a system that had a tiny leak that I could not find. Often, the system will cycle on the low-pressure control. low suction, high SH, high head, high to normal SC spells underfeeding metering device to me. Suction pressure: 110ish head pressure: 400 reached 550 when I put my wind breaker over the top - Condenser coil was clean Subcooling: 50 Superheat: 35. quark curseforge Unless overcharge, poor air flow across condenser, or non condensable in system. Learn how to determine the cause of low water pressure in your home, what you can do about it, and when to call in the pros. Specifically, this could be caused by a blockage in the refrigerant lines or a malfunctioning expansion valve. It turns out there is only 1 common cause for high superheat low subcooling: Technician saw pressure fluctuations of 450-580 or so high side and a 10 psi range on low side centered around 132 or so. HIGH SUCTION PRESSURE / LOW HEAD PRESSURE ISSUE. Of these, debris clogging or malfunctioning TXVs seem to be the most common problems. Restriction in the Refrigerant Flow. 50-70° subcooling (sky high) Head pressure climbs to 500-600 PSI, 145° saturation temp (sky high, climbs over the period of several minutes, hits HPCO). Conversely, letting air out does the opposite. Low wedge sandals are the perfect way to look stylish and feel comfortable at the same time. It was about 100f ambient. Aug 24, 2016 · If the suction pressure is 45 psi, (which converts to 22 ° F) and the suction temp is 32 ° F, the system still has 10 ° F of superheat. Customer has a walk in freezer with a semi-hermetic condensing unit. High superheat is an AC problem that won't go away by itself (except due to the #4 cause). Feb 17, 2015 · If it was restricted or bad compressor valves the head pressure would be high and if evaporator fan was not working(it was) my head would still be normalrestriction will give low suction and low head because there's enough room for all the charge in the condenser in most cases. Feb 1, 2021 · However, systems that pump low-pressure, high-temperature liquids are most likely to experience problems. NPSHR (Net Positive Suction Head Required) is provided in the data material for all pumps. • Condenser fins are clogged, and the. low suction, high SH, high head, high to normal SC spells underfeeding metering device to me. A reduction in both the water flow and pressure.
Post Opinion
Like
What Girls & Guys Said
Opinion
4Opinion
As pressure decreases, so does saturation. System is a 2 y/o, 5 ton Trane heat pump. This means the heart, brain, and other parts of the body do not get enough blood. If the head pressure drops too low due to low ambient conditions, this can come into play and impact the. 1. Customer: what causes low suction pressure high head pressure and high superheat. Discharge superheat can be a good indication of compressor efficiency. Coils are clean and fan on high speed, suction pressure running. These calls are tough to handle because the compressor is still cooling, but not cooling to its rated capacity. Causes: A ratio of head pressure to suction pressure is your compression ratio. Hook-up refrigerant gauges to the pressure ports on the unit. R134a, AEA4440YXA hermetic. Welcome to our article on understanding the impact of non-condensables in a refrigeration system. I open up the duct and the other hvac guy has put in a 3ton acoil. The pool filter pressure should be steady, operating in a range of +/- 10 psi. refrigerant overcharge. Low fuel pressure results in several issues for the engine, including rough idle, poor performance and decreased fuel economy. kdean1, buttwheat liked this post. By monitoring these pressures over time, technicians can diagnose problems early, preventing more significant issues down the line. The most common causes of pressure in the head and face include allergies, ear infections, the common cold, muscle tension, sinusitis, stress and tension headaches When it comes to upgrading your shower experience, one of the key factors to consider is water pressure. Busting my brain on this one. It ran for about 15 minutes. kroger huntsville texas This happens because more heat of compression will be generated when compressing the gases through a greater pressure range. Hydraulics. If you want to predict the system pressure head, you will have to subtract total suction pressure head from total discharge pressure head with the aid of a calculator. Clean walk-in cooler and walk-in freezer condenser coils. I have a Trane condenser and furnace. The high head leads to poor heat rejection and the higher pressures can force more of the available refrigerant into the evaporator and show up as normal or high suction pressure with normal or low superheat. I put my guages on at heat mode and it would trip discharge line temp at 650 PSI (154. This is the first in a series of free practice tests on handling refrigerants in low-pressure appliances and servicing low-pressure equipment. R134a, AEA4440YXA hermetic. I know this is a vague question but i wanna get all possible answers. Heat pressure is low and suction pressure is high. Negative suction pressure, often referred to simply as suction pressure or vacuum pressure, is a measure of the force created within a pump system to draw in fluids or gases from their source. Dec 20, 2023 · Imagine filling a balloon with air; as more air goes in (head pressure), the balloon expands (suction pressure decreases). Low condensing (head) pressure. Low condenser split. High suction pressure. It kept short cycling but was giving off 100 f supply. corcraft catalog Not all impeller centerlines correspond to the pump centerline. High head pressure. Low pressure at the pump inlet can cause cavitation, which occurs when the liquid entering the impeller eye drops below its liquid vapor pressure and vaporizes to form bubbles (NPSHA) compared to the net positive suction head required (NPSHR) of the pump6. High head pressure and low suction pressure in a straight A/C can be caused by various factors. High side stays same, low side pumps down. Came across another Rheem recently with a high head pressure in heat mode Head pressure slowly climbs to above 600, suction pressure is normal not low at all. 16+yrs HVAC/R service. A technician has found an air conditioning system with a leak in the liquid line. You've probably heard that high b. increased system operating efficiency d. Of these, debris clogging or malfunctioning TXVs seem to be the most common problems. Often, the refrigeration equipment is still running, but the product temperature is suffering about 7 to 10°F. High head pressure B. High liquid level C. Low head pressure D. The fact that these readings are normal indicates the low suction pressure is not caused by low refrigerant, but insufficient heat getting to the evaporator. In equation form: NPSH = P. Nov 11, 2022 · Low suction pressure and high head pressure is a condition where there is a decreased refrigerant pressure in the AC system and at the same time a high output pressure in a compressor. It turns out there is only 1 common cause for high superheat low subcooling: Technician saw pressure fluctuations of 450-580 or so high side and a 10 psi range on low side centered around 132 or so. High Head Pressure, Normal Suction Pressure Low head pressure is caused by a variety of factors, including the size and shape of the container from which water is drawn, the rate at which water flows through those pipes, and even changes in temperature. zips car wash veterans day Your high side is a little low. NPSH increases as the square of the pump flow rate near and above the design. 9. But there's a silver lining. G) f= correction factor. inefficient condenser B. CAUSE #2: Defective, plugged, or undersized. A high-head pump produces more pressure and will push liquid up further - whereas a medium head pump has more flow, but less pressure and therefore will not push the liquid as high. It will not be able to provide. They get stuck sometimes. Not a lot of info here but based on what you gave us you have low head and high suction and possibly low delta t which screams bad compressor. The compressor is now seeing. This is the minimum acceptable pressure head at the pump suction. I have checked for a stuck liquid line solenoid but this system does not have one, and I checked the reversing valve and its operating correctly. The saturated temp for 310psi is right at 99F. high ambient temperatures or reduced airflow through the condenser an overcharge of. Indoor heat load is too high. Low Refrigerant Charge (Low Subcooling) Or High Refrigerant Charge (High Subcooling) The most common cause for non-normal subcooling is a wrong refrigerant charge. unit has history of failing compressors.
Diagnosing Low Subcooling and High Superheat To make the term net positive suction head (NPSH). When a refrigeration system that produces low or no cooling has low suction pressure, high head pressure, and high evaporator pressure, it probably ___. suction and pressure lines on the compressor - reversed • The compressor magnetic clutch does not engage - hub slips on the pulley. If time and circumstances do not permit a technician to perform the superheat/ subcooling methods the refrigerant charge can be quickly checked by monitoring suction pressure, head pressure, and a liquid lines ____ High suction pressure low head pressure: In the air conditioning system if the suction side the pressure is increasing continuously then the low head pressure will be increasing inside the system. A liquid restriction would result high superheat (warm suction line). High Head Pressure, Normal Suction Pressure Low head pressure is caused by a variety of factors, including the size and shape of the container from which water is drawn, the rate at which water flows through those pipes, and even changes in temperature. Unless overcharge, poor air flow across condenser, or non condensable in system. Figure 5 The effect of low level on the pump suction After all if you have a high head, which means a high pressure, shouldn't that push more water through the pipes Since total head is the difference between the discharge head and the suction head using head makes it easy to evaluate the suction head, How to Identify and Fix Low and High Refrigerant Charges Undercharge symptoms: Low discharge and suction pressure. krave trainwreck shot review Net positive suction head for a pump is the difference between the suction pressure and the saturation pressure of the fluid being pumped. As others have said it sounds like a TXV and maybe low on juice. The high sub-cooling puzzled me. Not all impeller centerlines correspond to the pump centerline. High head pressure. make an appointment at lenscrafters The indoor temp is 87 degrees. Jun 28, 2013 · I injected super seal in a 410a system that had a tiny leak that I could not find. The system has one condenser fan, it is running in the proper direction, pulling normal amps, and it's capacitor is good,, not showing a low reading. Proper head pressure d. lothric knight greatsword The system has one condenser fan, it is running in the proper direction, pulling normal amps, and it's capacitor is good,, not showing a low reading. Probably flashing off at the valve. The suction pressure, also known as the low-side pressure, for a 404A cooler typically falls between 55-70 psi What causes high suction pressure 404a?. The suction pressure, also known as the low-side pressure, for a 404A cooler typically falls between 55-70 psi What causes high suction pressure 404a?. Low pressure at the pump inlet can cause cavitation, which occurs when the liquid entering the impeller eye drops below its liquid vapor pressure and vaporizes to form bubbles (NPSHA) compared to the net positive suction head required (NPSHR) of the pump6. The low head pressure that the compressor has to pump against will also reduce the amp draw.
If you want to predict the system pressure head, you will have to subtract total suction pressure head from total discharge pressure head with the aid of a calculator. Low suction pressure Have a walk in cooler running head pressure 100 over 15 but not cooling and temperature outside is -15 has a hot gas bypass and crank case heater it's run sight glass has. I ran it undercharged for about 15 mins and the suction was at 40 psi with. Heat pressure is low and suction pressure is high. Negative suction pressure, often referred to simply as suction pressure or vacuum pressure, is a measure of the force created within a pump system to draw in fluids or gases from their source. 25 lbs) and pressures did not change Switch it to heat mode, I bet the head pressure sky rockets. Symptoms include poor cooling or heating. As an example, Trane includes a pressure curve chart with many heat pump condensing units. Learn about what can cause it. Beyond this pressure window, you have an R22 pressure chart for the high and low side above. • vent refrigerant to the atmosphere And, just as common, is suction pressure and/or head pressure being involved in the cause. Although cryptos enjoyed strong performances earlier, a lack of fundamental catalysts may apply some pressure on the sector. Conversely, letting air out does the opposite. My HVAC contractor recently saw head pressure of 350-400, normal to low suction. Jun 28, 2013 · I injected super seal in a 410a system that had a tiny leak that I could not find. The only sure way to identify cavitation is to calculate the net positive suction head available (NPSHA) at the pump suction and compare it to the manufacturer's supplied curve for net positive suction head required (NPSHR) Because the suction is at low pressure and discharge is at high pressure, there is internal leakage from the pump. What effect does low head pressure have on non balanced port txv's? Help; Remember Me? Home; FAQ. Could the super seal be clogging the txv or evaporator or condenser coils? Today I was doing a maintenance check on a three year old Carrier Heat Pump M# 38YKCo36 321 S# 4202EO2360. Replaced txv and had same problem. That means that Third. What's head pressure doing ? The only time I saw this was a bad Txv, and it only did it cool mode. has a low-side restriction When a refrigeration system does not provide its evaporator with enough liquid refrigerant, the evaporator exhibits ___. Worn compressor piston rings. honda rancher stuck in gear Suction pressure will be higher than normal because discharge gases have leaked through the rings and into the crankcase. Low Load. see our complete list of causes of high head pressure at REFRIGERANT HIGH HEAD PRESSURE DIAGNOSIS. low-temperature, low pressure high head pressure. 2 years later I come across the problem of low suction pressure normal head pressure. Expert Advice On Improving Your Home Videos Latest View All Guides Latest View All Radio Show. Study with Quizlet and memorize flashcards containing terms like 1. Good air flow through evaporator and condenser. 5 ton 16 seer payne condenser with a 2 ton payne N coil with a txv already installed 155 suction pressure 280 discharge pressure 4 amps 10 degree sub cooling which condenser calls for only 3 degree superheat havent ran into a problem like this before but called tech support they said bad. Temp at the vent in rooms: 56. If the head pressure drops too low due to low ambient conditions this can come into play and impact the. Came across another Rheem recently with a high head pressure in heat mode Head pressure slowly climbs to above 600, suction pressure is normal not low at all. This will cause low subcooling and low head pressure. Non-condensables, such as air and nitrogen, can sneak into the system through improper service procedures or leaks. You are pulling in 100 degree air so your evap is going to have a really really high load causing your suction pressure to be high. The high side pressure, in contrast, refers to the refrigerant pressure in the discharge line. What are suction pressure and head pressure? Web low suction pressure and high head pressure occur when there's a drop in refrigerant pressure in the ac system,youtube High Head And Low Suction - Web high suction pressure is the present of refrigerant to the compressor which is carrying by the suction line into The capacity of a compressor can be affected by a refrigeration system's ever-changing pressures. The high-pressure side contains a narrow diameter when compared with the other side. - 2 ton York runs 40degrees F on low pressure side and 110degrees F on high pressure side. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Low suction pressure, low discharge pressure because of restriction. This condition is mainly caused by a defective or malfunctioning TXV valve. The compressor is now seeing. High Liquid Pressure / High Subcooling: Compressor Runs but Does Not Pump: High Suction Pressure / Low Liquid Pressure: Compressor Tries to Start But Does Not: Low Suction/ Low Superheat (fixed metering device) Low Suction Pressure / High Superheat: Low Suction/ Normal Superheat (TXV) Odor and/or "Green Slime" In Refrigeration System. It adds up to a comprehensive offering to support nearly any hydraulic circuit filtration need. social security office independence mo Now, you consult the target superheat chart here at 82°F outdoor temp (dry bulb temp. Insufficient refrigerant in system. I was working on a customers heat pump today, A lennox HPXA19-060-230-02 with A cbx32mv-060-230-6-02. Insufficient refrigerant in system. But the low air problem would result in high head pressure in the heat cycle. low suction pressure b. pressures are 235 psi head pressure and a 28psi suction pressure. Available NPSH (or NPSHA) is simply a difference between this total suction head, as discussed above, and vapor pressure-expressedas head-in feet. Causes of high head pressure low suction pressure. Check fan motor and its electrical circuit. what is the lowest outside ambient temperature that balanced-port valves can typically work without head pressure control? 35°F. System Information R22 2. Discharge was a bit low, but I was willing to live with it if my suction. without considering the issue of non-condensible gases (air, nitrogen, hydrogen, etc These gases will leak into low temperature systems whose suction pressures are below atmospheric. I know this is not normal readings and since it's a scroll compressor, I am thinking about replacing the TXV. The "changeout team" that installed the condenser saw exactly the same situation on the new unit but the head pressure starts creeping up really high before the suction side can. If we were to place that same open container of cool water on the surface of the moon, it would boil away, similar to the ammonia. Defective Discharge valve: Indication: Continuous running of Compressor.