High pressure lockout on lennox heat pump?
Follow
11
High pressure lockout on lennox heat pump?
At 10 degrees its about 3/4 the cost. Now the heat pump starts out fine in heat mode but gradually builds high side pressure till it's over 600 lbs. Every year we have to reset this customer heat pump and find no issues, maintenance is done every year. Delivering effective temperature and humidity control, and efficient energy usage, Lennox heat pumps keep your home's temperature exactly where you want it. Outdoor thermostat maintains the heating load on the low power input as long as possible before allowing the full power load to come on the line. This happens if condenser is dirty or if you are overcharge. I have a lennox a/c system. are not to be used with other refrigerant flow control. This helps reduce moisture levels inside your home to enhance your comfort. These heat pump models have a control board which monitors equipment operation. Aug 5, 2012 · Here's some info that might help. Air conditioning or heat pump units with up to four stages of heat / two stages of compressor operation (two stages of heat pump heating, two stages of auxiliary back-up heating, two stages of emergency heating) Humidification measurement and control Dew point adjustment control Equipment maintenance reminders HVAC Technician: Tamar D Surely. XP17 heat pump pdf manual download. Customer: I need to diagnose a pressure switch lockout issue on a heatpump. Low Pressure Switch 7. Low airflow will cause high pressure trip. If the lock out due. This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control; Somewhat high discharge temperature; Low condensing (head) pressure; Low condenser split; and. If the heat pump cant keep up at that temperature, the furnace will come on any way. Yes, the pressure switch can become old and weak. Rheem Heat Pump: RPNL / RPQL. HPCO (High Pressure Cutoff) L2 code thrown periodically on heat pump. Your Trane heat pump might be on soft lockout because it has a faulty temperature regulator or a bad compressor. But now it is also happening during heating for the last 4 days it happened 3 times - always when the heat is supposed to kick on in the morning (I have it set at 62 during the night and 67 during the day). Over a At 50 and above, the heat pump is about 1/4 the cost of aux heat BTU to BTU. Rubber dampeners standard on all sizes to reduce sound levels. Then try to determine if the condenser fan motor randomly shuts off or does the high pressure control need replaced. Dave Signature Collection System. In EMERGENCY HEAT mode, all heating demand is satisfied by auxiliary heat; heat pump operation is locked out. I've changed the modes from ac to heating and the outdoor unit doesn't operate anymore (no cycling, heating I know something is up because whenever heat does come out, it's the emergency/auxiliary heat from the main furnace (ie much warmer air). Lennox ac pressure switch reset The pressure switch on a Lennox air conditioner is a safety device that is designed to prevent the air conditioner from operating if the pressure in the refrigerant system is too high or too low. ert Codes and TroubleshootingCritical alerts are displayed on the Home screen, in the Homeowner alert button, and. Compressor spins and rotates fan blade at normal speed. A hvac tech measured the system pressure last fall and found that while the system pressure was appropriate when. XP14 units are available in sizes ranging from 1 1/2 through 5 tons. I want to expand on our recent gas furnace troubleshooting series by going into each part of a furnace's operation sequence. Everything worked fine after that, at least up until a few weeks ago. Unit runs at low most of the time, using only. can generate heat down to -10F). Customer: my lennox thermostat is reading "ambient lockout". provisions for lockout. Known for their quality and reliability, Lennox products are highly regarded in. Kenya and Uganda have agreed on a route for a 1,500-km (930-mile) pipeline to pump oil from Uganda to the. Make sure it's set appropriately for the season. The method requires that you block sections. Both heating and cooling systems are operating at the same time. If the pressure switch is good, then check the airflow across the air handler. Is that one of the washable foam filters or an EAC? If it's a washable 1" filter try replacing it with a cheap disposable one. Furnace, A/C and heat pump specialist. he told me that he could tell when it had enough freon by the temperature difference in the two lines going to unit. Sound levels low as 76 dBA. High Pressure Lockout on a Carrier Infinity unit 102017 The ML17XP1 offers energy efficiencies of up to 1860 HSPF, equivalent to 1750 HSPF2, delivering comfort and energy savings at a more affordable price. In summer, choose “cool In winter, choose “heat Set it to “on” instead of “auto Most heat pumps have a 5-minute time delay, so wait momentarily to see if that makes the heat pump start Smarter Together. Minor Revision Number 230 = 208/230V-1phase-60hz5-5 TON HEAT PUMPS. The problem I have is the heat pump shuts down with a code of High pressure shut down. I want to expand on our recent gas furnace troubleshooting series by going into each part of a furnace's operation sequence. R-410a Refrigerant Pressure Readings R-401A pressures, quantities, data Questions & answers about refrigerant pressure readings in air conditioners, heat pumps, & other refrigeration equipment Heat Pumps and Electric Home Heating - Goodman Heat Pump trips High Pressure Lockout when defrost cycles are required - I have a new Goodman Model DSZC180361 heat pump which charge checked correct during summer. A heat pump requires a certain amount of refrigerant to function properly. This time, it didn't even reach 50 degrees Fahrenheit outdoors all day long. Imagine a chilly evening, you’re ready to relax, but your heat pump is on the fritz, … View and Download Lennox XP14 SERIES unit information online. I have a Carrier Infinity 24ANA7 that goes out on high pressure lockout at about 3:30AM every morning. Lennox produces heat pumps with efficiency ranges from 13 SEER 75 SEER 10 They are known as a premium HVAC equipment manufacturer. 5F in 30 minutes on the zone or zones. Rated according to U Department of Energy (DOE) test procedures. I have a customer that is experiencing random high pressure lock outs. This morning at 33 degrees outside temperature, the HP turned on by itself, as thermostat was setback to 64 degrees Turn the power off at the furnace and then back on, that will reset the pressure switch lock out on the heat pump I have a heat pump that several times during the cold months will run into a high pressure lockout. I dont have alot of Lennox experience but I know I dont like them as of now. Heat Pump Troubleshooting Problem #3: BLOWING COLD IN HEAT MODE. Of these, debris clogging or malfunctioning TXVs seem to be the most common problems. what does this mean? Carrier I would set the system to lock out at 35 degrees. 5F in 30 minutes on the zone or zones. Download 54 pages 9 If a Lennox heat pump is not working properly, reset the system before contacting technical support. HVAC Technician: Brian HVAC Guy. If you have to reset your heat pump because it keeps running off on its own or doesn't perform the desired function, the first step is to check the settings on the thermostat and adjust them accordingly. They'll measure the pressure while it tries to close during a heating cycle as well as its standard operating pressure. what does this mean? Carrier I would set the system to lock out at 35 degrees. I was unable to test the unit S/C and S/H accurately, due to the High Side pressure building up so fast with in a minuet will be hitting 400psi and blow the low side would sit at about 50psi. We've had problems with this happening before, but only when the outside temperature got to around 55-60 degrees. A High Pressure Lockout is indicated by a 3-Flash LED pattern on the outdoor unit control board XP14 Corp. After a six-hour compressor crankcase warm-up period, the thermostat can be switched to the HEAT setting and normal heat pump operation may resume. Lennox heatpump: High pressure lockout; light stays on. 4 ton; 14-15 seer?. If they find a problem, an obstruction impacting airflow is the most common culprit. Do you happen to have access to a set of refrigerant gauges so we can troubleshoot this? Alert code 411 OU Low Pressure Switch Strikes Lockout, Lennox furnace and condenser. I was unable to test the unit S/C and S/H accurately, due to the High Side pressure building up so fast with in a minuet will be hitting 400psi and blow the low side would sit at about 50psi. If the system was charged in the cooling mode it could be overcharged when the unit goes into heating mode 02-02-2009, 08:43 PM #4. A pin should be in one of these holes. I'll fill you in on what the pressure switch does and why it's important. 2015 Lennox heat pump If you get an Error Code 413 on your Lennox HVAC system, this video will show you how to clear the error code and get your unit to restart. The XP25-060-230 uses revolutionary Precise Comfort™ technology to maintain an ideal temperature and perfect humidity under any conditions, all while saving hundreds of dollars in energy costs. In this article, I'll go over what you should do if your AC's high pressure switch trips. Step Four: To replace the furnace control access panel, follow these instructions in reverse. my son has a lennox XP15-042 heat pump and has had problems with a compressor lockout code of 3 yellow flashes. HVAC Technician: André R First step, is to perform a reset. I can trip the circuit breaker to disconnect power to the unit for a few minutes then turn the circuit breaker back on and the Heat pump will begin to work fine for approx 2. For the first 5-7 years had no problems with the heat pump, but for the past 5+ years, it will randomly lockout with HPCO (L2). theoriginalmarkz live A two-stage heat pump has a compressor which is capable of operating at a high and low speed, improving its ability to maintain the temperature in a home with greater precision Regardless of the season, keeping your home at an ideal temperature ensures that everyone who lives there is always comfortable and all the other systems and appliances in your hom. Expert Advice On Imp. Mild Weather Kit can be field installed, allowing heating operation above 75 F. 3 years i just changed the thermostats to WiFi and it was working last night. my son has a lennox XP15-042 heat pump and has had problems with a compressor lockout code of 3 yellow flashes. The blue line is the heating capacity of the heat pump. This process warms the indoor space Lennox SL25XPV Heat Pumps. If they find a problem, an obstruction impacting airflow is the most common culprit. 38,110 Satisfied Customers I have a e201 code on lennnox. Both brands have the same parts/repair cost which ranges from $15 to $150 (low); $250 to $600 (average); $800 to $1,700 (high) Lennox heat pump lasts around the average of 10 to 15 years while Trane heat pump has an average lifespan of 15 to 20 years, but it can last much longer if properly maintained. Heat Pumps; 1 Phase Heat Pumps; Lennox Merit ML17XP1-042, 3. Entire coil is accessible for cleaning. Also for: Xp21−024, Xp21−036, Xp21−048, Xp21−060. First time owning a heat pump and have 2 questions on my Lennox XP25 (2320 HSPF. Some Lennox heat pump systems come with a subcool chart next to the approach chart. … Sunday my 3-month old Lennox XP-16 quit working. richh des damion dayski the tech that installed it had bad set of gauges when he added freon. Oct 4, 2020 · The LED lights indicate that the high-pressure switch is preventing the heat pump from turning on. Therefore, due to this lack of air, the system ends up with a high-pressure. That is 370% efficiency. The water pump on a Chevrolet Aveo with the 1. There are several reasons why a heat pump may go into high pressure lockout mode. And to wrap things up, I'll give you five easy things to check when you're troubleshooting a furnace pressure. the vibration noise in my bedroom 8 ft away was extreme. Panel is capable of controlling multi-stage equipment, 2 heat / 2 cool conventional heating/cooling systems and. In this article, I'll go over what you should do if your AC's high pressure switch trips. This feature is designed to protect the compressor and other components from damage, ensuring the longevity and efficient operation of the heat pump system. A heat pump is an all-in-one heating and air conditioning system that works year-round to keep you comfortable. com I have a Lennox 14HPX-042-230-11 heat pump. 1 ©2017 Lennox Industries Inc 1408-L10 March 2, 2017. Secure and convenient, mini-split systems are easy to install, using a compact indoor and outdoor unit connected through a small hole in your wall. Heat pumps are an energy-efficient way to heat and cool your home. I have replaced the capacitor and that does not fix it. - Answered by a verified HVAC Technician The efficient EL22XPV variable-capacity heat pump is your digital bridge into a world of perfect air. Use the Lennox heat pump troubleshooting guides below: 855-339-6245 Lennox Heat Pump Troubleshooting High Pressure Switch Lockout: Lennox MS8 Heat Pump Troubleshooting. Advertisement All of the hydraulic systems on a backhoe get their hydraulic pressure from a hydraulic pump. First, regularly replace air filters, about once a … My Lennox compressor (11yrs old) stops running every few weeks in summer. hermione granger homeless fanfiction The heat pump was running in normal heat mode (not in defrost) and the high pressure switch tripped. 5 tons 036 = 3 tons 042 = 3. The Lennox ComfortSense ® line of thermostats makes programming an energy-saving schedule remarkably easy. "I would recommend this (iComfort Wi-Fi®) product to anyone who is installing any new HVAC system, or even add it to your existing. Hello, we recently moved into a newly constructed house (Virginia) with a dual fuel (propane) heat pump on the first level. Sound rated in Lennox reverberant sound test room in accordance with test conditions included in AHRI Standard 270-2008. But that's high pressure trips. Feb 2, 2009 · When you have a high efficient heat pump it requires a matched indoor coil. to low pressure occurs at an outdoor ambient temperature below 5°F, the defrost control will automatically exit the lockout mode when the outdoor ambient temperature rises 5°F. Another cause of a hard lockout flashing on your Trane heat pump is its fan motor becoming bad. I discovered the unit was faulting when I switched it to heat mode. is this possible? and what are the possible causes of high pressure fault? Hi, I have a 6-yr-old Lennox XP17 heat pump with no heat strips, and a NG furnace for backup. 4K views 1 year ago #rheem #hvaclife #hvactechnician Was found lock out on HPS fault, but ran fine. HFC-410A refrigerant only. If that is not the case, you should have the unit tested because it is likely the pressure is low. the manifold gauge set. Here's some info that might help. Connect a cylinder of dry nitrogen with a pressure reg. For the first 5-7 years had no problems with the heat pump, but for the past 5+ years, it will randomly lockout with HPCO (L2).
Post Opinion
Like
What Girls & Guys Said
Opinion
14Opinion
4 ton; 14-15 seer? I have the serial # if that helps. ert Codes and TroubleshootingCritical alerts are displayed on the Home screen, in the Homeowner alert button, and. It’s the last thing you want to deal with after a long day. Press to activate "night-mode". Aug 5, 2012 · Here's some info that might help. By operating at its lower speed, air spends more time in contact with the outside coil, the cooling engine of your air-conditioning unit. Would like to set it so that the furnace doesn't come on until it gets. What is this about? Thank you. The indoor coil and outdoor coil are located opposite each other. Use the Nordyne heat pump troubleshooting guides below. If outdoor temperature is below the low balance point, only auxiliary heating will operate - default 25°F (-4 If outdoor temperature is in-between the high and. Radiator Labs, a company born to solve steam. Too much or too little refrigerant can cause pressure levels to rise and set off the high pressure lockout. However, their use of unique parts can lead to higher maintenance costs, and the premium pricing may deter budget-conscious consumers. Why do hugs feel so good? Why do massages de-stress us? Why do some people like sleeping with heavy blankets, even. Observe refrigerant pressures (may need to switch Red hose to liquid line for cooling High Pressure) Unit should terminate defrost somewhere around the following pressures: 125 - 140 Suction ; 300 to 400 Discharge. Step 3. Its an XC25-036-230-01 and - Answered by a verified HVAC Technician P = Heat Pump Outdoor Unit X = R-410A. devine isd pay scale Hydraulic pumps use liquid to convert mechanical energy into pressure and flow. Heat Pump Pressure Switches. Page 18: Heat Pump 24. ok, so maybe the high pressure light was "predicting" that state because it didn't receive a water flow signal within the half second of startup? Lennox DLSC SL25XPV-048, 4 Ton, Up to 218 HSPF2, 208-230 VAC 1 Ph 60 Hz Quantum Coil Variable Capacity Heat Pump. Both units were apart of a new system install 12 years ago. Is this fatally serious, ore can it wait until tomorrow ? Pressure at Transducer has fallen below settings. A High Pressure Lockout is indicated by the following LED pattern on the outdoor unit control board: Green = Off X/L Output. heat exchanger assembly condenser coil door interlock switch cold header (collector) box combustion air inducer blower access panel burner access panel flue collar combustion air pressure prove switches* primary limit warm header (collector) box gas valve and manifold secondary limits (2) power choke (5 ton only) blower motor transformer. The Defrost Control Board was showing solid green light on the DS2 LED indicating High Pressure Lock Out. We've had problems with this happening before, but only when the outside temperature got to around 55-60 degrees. Overall, customers like that their Rheem heat pumps are reliably efficient and easy to operate Lennox. Does anyone know why my pressures reach this high when heating, but are perfect in cooling? Im tripping on high limit in under a minute. The 14HPX is a residential split-system heat pump. Charged the system back with 410a, and ran in cooling, was getting around 20-30 on the suction side and about 180-190 on liquid side. kahoot random trivia Another cause of a hard lockout flashing on your Trane heat pump is its fan motor becoming bad. +Remove the control box from the gas block. The higher the value, the better m. so here are some reasons for both. Jus started about 7 Insufficient refrigerant is the first reason for low pressure lockout. We keep getting error code 413 for our heat pump xp21 Installer says they fixed it Replaced accumulator and after recharging normally in cooling mode, trips out in heat mode on overpressure. Elite EL22XPV Series heat pump pdf manual download. Hi-Capacity Liquid Line Drier. XP14 SERIES high efficiency residential split system heat pump unit. The problem I have is the heat pump shuts down with a code of High pressure shut down. System fault and lockout LED (DS11 / DS14) alarm codes takes precedence over system status LED codes (cooling, heating stages or defrost/dehumidification). Low pressure switch strikes lockout. Installed july 2017. My Lennox compressor (11yrs old) stops running every few weeks in summer. The shutoff switch itself costs an average of $30 to $150. hippy clothing uk Allows flexible installations on roofs with sloped or uneven angles. Then try to determine if the condenser fan motor randomly shuts off or does the high pressure control need replaced. The residential water well owner should set the pressure in a bladder tank at 2 pounds per square inch lower than the cut-on pressure for the well pump. The TPAH4 is a commercial split-system heat pump. Congratulations! You have made a wise choice with the purchase of your Lennox HPXA12 heat pump with R410A refrigerant. + Check injection pressure during start-up (Value for High Heat) + Remove the air from the Gas pipe-work + Adjust the injection pressure to high heat value. Lennox XP14 - repeating 5-min anti-short cycle mode (cooling) I have a Lennox XP14 heat pump and recently it has been acting up. The unit will trip on the compressor relief valve in heating. Fully gasketed around curb perimeter and supply and return openings. It worked great all summer but now that winter has hit it has been very problematic and expensive to run. are not to be used with other refrigerant flow control. Switch opened two times in 6 hours. Cooling compressors, heat pump compressors and some other electrical motors can run backwards too: well pumps, fans, even an A/C or heat pump compressor. Remember that that switch comprises several delicate parts, including a rubber diaphragm and spring wire.
Four-Way Reversing Valve 7. HPXA16 Series heat pump pdf manual download. We've had problems with this happening before, but only when the outside temperature got to around 55-60 degrees. Cooling compressors, heat pump compressors and some other electrical motors can run backwards too: well pumps, fans, even an A/C or heat pump compressor. my tech replaced the high pressure switch and that seemed to fix it. During hot weather, the continuous air circulation helps to lower humidity level inside your home for even more comfort. Page 31 High Pressure Switch S4 Terminal Strip TB2 PHK-05, -07, -10 S4 is a N auto-reset high pressure switch located on All heating elements require either a second-line voltage the discharge line. CLICK HEREPress it and then make sure the filter is clean and make sure the condenser is clean. m4a mp3 converter Learn about the high pressure switch sequence of operation for the Lennox International Inc, Dave Lennox Signature Collection XP17 System HEAT PUMPS. Contractor's Assistant chat Customer: We have a Lennox heat pump G24M3/4-100A-2. In EMERGENCY HEAT mode, all heating demand is satisfied by auxiliary heat; heat pump operation is locked out. At much lower temperatures - say 10°F winter temperatures - an average heat pump efficiency is about 2 That is 230% efficiency. Make sure the setting matches the installed heating and/or cooling system. 2 Flashes at Thermostat = Soft Lockout. This is not a complete list **** The below info regards heating mode only High pressure trip: --- The evaporator coil inside is the refrigerant condenser. Here's the equipment that the builder installed: Gas Furnace - American Standard AUH2C100A9V4VB. fake cash app payment generator 2021 After the heat pump lock out is expired, the heat pump is once again used as the primary heat source. I have had this same issue on a Lennox heat pump myself from new. HPC SYSTEM LOCKOUT LOW PRESSURE FAULT ® ® MULTI-UNIT COMM FAULT OTA. 06 - Lennox Furnace Draft Inducer Motor Assembly The draft inducer motor assembly draws air into the heat exchanger and then exhausts it out the flue. Also for: Xp14−018, Xp14−024, Xp14−030, Xp14−036, Xp14−042, Xp14−048, Xp14−060. Why do hugs feel so good? Why do massages de-stress us? Why do some people like sleeping with heavy blankets, even. I'll fill you in on what the pressure switch does and why it's important. and line set as outlined in the XP16 Lennox Engineering Handbook use in check / expansion valve (CTXV) systems only and. remote social work jobs near me When your heart pumps blood into your arteries, the pressure of the blood against the artery walls is called your blood pressure. High Liquid Pressure / High Subcooling. Customer: prior to leaving for a few days I vacuumed the air conditioning unit located outside and put the thermostat to spring fall mode If you're looking to reset your Lennox air conditioner, finding the reset button is the first step. There is several factors that can cause hight pressur. A heat pump is an all-in-one heating and air conditioning system that works year-round to keep you comfortable.
Both heating and cooling systems are operating at the same time. Remember, Air Conditioning begins with AIR. They'll measure the pressure while it attempts to close during a heating cycle as well as its general operating pressure. Entire coil is accessible for cleaning. The problem I have is the heat pump shuts down with a code of High pressure shut down. It looks like there may be multiple problems at hand, so it's important to address each one effectively. Check Refrigerant Pressures. Advertisement All of the hydraulic systems on a backhoe get their hydraulic pressure from a hydraulic pump. The lockout flashing codes now (either I made a mistake before or they have changed) show LED1 Flash, LED2 Off. All TPAH4 units utilize scroll com-pressors. Example: outside temp now is 50 deg. In communicating system, the iComfort®-enabled thermostat has a separate built-in 5-minute non-adjustable short cycle protection. How bad were filters? My Lennox 14HPX-303 is in low pressure lockout. r nbaspurs Plumbing Component Locations. They do this through a reversible refrigerant cycle within the system. The heat pump was running in normal heat mode (not in defrost) and the high pressure switch tripped. Pretty much immediately I had to replace the capacitors and blower motors for BOTH the inside unit and outside compressor. Now some are auto resets and some have to be manually reset. 4K views 1 year ago #rheem #hvaclife #hvactechnician Was found lock out on HPS fault, but ran fine. If you have to reset your heat pump because it keeps running off on its own or doesn't perform the desired function, the first step is to check the settings on the thermostat and adjust them accordingly. Problem Possible Cause; Unit does not operate immediately when restarted. Allows flexible installations on roofs with sloped or uneven angles. High and low pressure switches may be installed on the refrigerant tubing. E30 Smart Hub with Cover Removed Smart Hub LED Indicators Set the unit type jumper for the type of indoor unit being used (see "Figure 1. an approved indoor air handler or coil XP16 Product Specifications bulletin (EHB) for approved. How bad were filters? My Lennox 14HPX-303 is in low pressure lockout. Compressor delay (30 seconds, field selectabl. It keeps triggering the high-pressure cut-off on the outdoor unit. 3 months on a 5" filter is short but if the dust is very fine, that stops up airflow pretty quickly 02-25-2013, 05:06 PM #3 Heat Pumps and Electric Home Heating - Low Pressure Lockout + High Pressure Fault Codes: No Heat Pump - My electric bill is very high and found that my heat pump system is using Aux heat full time. Rechecked accumulator connections (inlet from reversing valve - outlet to compressor suction). If you have a set of gauges, check to make sure that the high pressure switch is in fact tripping when it should, typically around 600 PSI. Heat pump units operate satisfactorily in the heating mode at outdoor air temperatures up to 75 F. my uscis gov account Problem was found to be a loose wire in a splice that led to a high pressure switch. Lennox heatpump: High pressure lockout; light stays on. They'll measure the pressure while it attempts to close during a heating cycle as well as its general operating pressure. After the heat pump lock out is expired, the heat pump is once again used as the primary heat source. Go to the outside unit and look down towards the back near the ground for a RESET button. It keeps triggering the high-pressure cut-off on the outdoor unit. Rechecked accumulator connections (inlet from reversing valve - outlet to compressor suction). I have a Carrier Infinity 24ANA7 that goes out on high pressure lockout at about 3:30AM every morning. This morning at 33 degrees outside temperature, the HP turned on by itself, as thermostat was setback to 64 degrees. 08 x cfm airflow) If you're looking for help fixing your Lennox Heat Pump, look no further! Our comprehensive Lennox Heat Pump Troubleshooting guide will explain common issues. TPAH4 series units are available in 3, 3-1/2, 4 and 5 ton ca-pacities. Its an XC25-036-230-01 and - Answered by a verified HVAC Technician P = Heat Pump Outdoor Unit X = R-410A. The unit will trip on the compressor relief valve in heating. Comprehensive configurations meet a wide range of applications, making it the most flexible product line Lennox has to offer Features.